Home
Product Catalog
Split Solar Water Heating Syst
solar light
 sanitary  ware
solar intelligent controllers
All-glass evacuated tubes
Documents
News
Contact Us

Split Solar Water Heating Syst 

The split solar water heating system is such a system that separates the heat collector from the water tank,and transfers the solar energy collected by the heat collector to the water tank for the hot water through the natural or forced cycle of medium. Himin family split solar water heating system has such merits as large water storage,good heat-collecting effect,long insulation work time, intelligent operation,load-bearing running,and convenient and reliable use. So it is the ideal selection for home hot water scheme.

The characteristics:
1. Special design for luxury villa
Presenting unique charm & spirit of successful person, as well as experiencing worshipful life
2. Pressure hot water, comfort bathing
It applies pressure bearing design, & in case of switch-on, it shall have pressure hot water immediately with strong water outgoing, large water quantity & flow.
3. Collector part module for freely assembly
Modulus collector component constituted by high temperature special effect pipe, & can be freely assembled as per requirements.
4. Intelligent control with complete function
Control system of integration & intelligentization: convenient & quick;
Indicating pressure & multi point water temperature.
5. Diversification of installation position, perfect combination with building
Heat collector shall be suitable for multi building style with diversification of installation position.
6. Separate type installation; simple & convenient.
Heat collector shall be separated with water storage tank, & water tank position shall have no limit.Standard modularization for fast assembly: easy & quick.
7. Use with cooperation of auxiliary energy resource
Auxiliary energy resource interface shall be reserved so as to achieve full day hot water supply with combination of electric energy, fuel oil & gas boiler.

* Heat pipe vacuum tube solar collector

* Wilo hot water pump (RS15/6)

* Three sensors differential controller

* Porcelain enamel pressure storage tank with coil exchanger

* Air Vent

* Electric Booster: 1.5KW

* Expansion tank

* Pressure gauge

* Filling & flushing valve

* P/T valve

* One way valve

* Mag. Anode

* Vacuum valve

 

 

Style

Solar Collector

Pressurized Tank

Qty.per20'/40'
Container

 

Model

Tank Capablity

Heating exchanger

 
 

BLS-IV-A-100-I

BLS-III-A-S-58-15

100L

One

50/108

 
 

BLS-IV-A-150-I

BLS-III-A-S-58-20

150L

One

37/80

 
 

BLS-IV-A-200-I

BLS-III-A-S-58-25

200L

One

30/64

 

BLS-IV-A-200-II

Two

 

BLS-IV-A-250-I

BLS-III-A-S-58-30

250L

One

26/56

 

BLS-IV-A-250-II

Two

 

BLS-IV-A-300-I

BLS-III-A-S-58-36

300L

One

20/45

 

BLS-IV-A-300-II

Two

 

BLS-IV-A-400-I

BLS-III-A-S-58-48

400L

One

15/33

 

BLS-IV-A-400-II

Two

 

BLS-IV-A-500-I

BLS-III-A-S-58-60

500L

One

14/30

 

BLS-IV-A-500-II

Two

 

solar vacuum tube
solar vacuum tube
Valve and Meter  
 
air_vent_valve connect flexib pipe to connect flexib pipe connect flexible pipe to maniflod or copper pipe
connect tank Female outlet to flexible pipe connect tank to flexible pipe CORRUCON
     
  pressure controler temp valve
 
  TPvalve TWINPIPE1 TWINPIPE2  
       
  TWINPIPE3      
 

3、 

 

 

 

      


Temperature & Pressure Safetly Valves
Operation Instructions
一、Using Method
Temperature and Pressure Relief Valves is suitable for bearing the pressing type solar water heater, gas heater, electric heater , water heater of fuel, water heater of heat pump, sensitive function heater, etc. various kinds of heaters( such as the boiler) and hot water containers .
二、Technical Parameter
·Standard setting: 75,87,100,125,150psi(0.5、0.6、0.7、0.86、1.0MPa)
·Temperature relief: 210℉(99℃)
·Dimensions/Weights


MODEL

Size
in

Import x Export
in

A
in

B
in

D
in

T
in

Weight
Oz(g)

Temp. Steam
Rating BTU/hr

WYA-15

1/2

R1/2xRp1/2

12/3

31/4

11/8

4

8.4(237)

15,000

WYA-20

3/4

R3/4x Rp3/4

12/3

31/4

11/8

4

9.1(258)

100,000

三、Installation
·Temperature and Pressure Relief Valves should be installed on the water heater top or side.The Temperature sensing element must be inmmeresd in the water within the top 6″of the tank.
·The eliminating pipeline should be installed under the relief valve.Its terminal station distance in floor drain should be greater than 6″to make it easily remove and observe water.

 

 

 


           

四、Safeguard And Maintenance:After installing,water heater users must lift the relief valve handle once at least every year,so as to ensure that unblocked things in the waterway of the relief valve.Before operating handles,please check the elimination pipeline which joining the relief valve,guaranteed that the hot water from the relief valve discharge the proper place,otherwise it may cause the bodily injury.If the handle is lifted,without water flowing out,it proves that the relief valve is invalid.Then it should turn off the water heater immediately and ask pipeline personnel check and repaire.
五、Designed and checked under “ANSI Z21.22”

Super heat pipe series solar water heaters

Blessingsolar heat pipe has a low thermal capacity, and has rapid heat exchange (it is 1000 times of copper heat exchange speed, so it is an available fast heat exchanger. Heat exchange rate is up to 99%. The startup is fast, collect solar energy fully, at 25℃,5 seconds can startup heat. At the same time, it has heat exchange unilateralism diode function system, for example: heat energy exchange is a direct progress from heat absorber to water. But it will not back up or reversal in the water. Because of matter physics effect in the heat tube and especial construction of condenser, the biggest work temperature of this system will be controlled; this particular characteristic ensures the stability under special conditions.

The solar collector tubes have especially excellent ability of absorbing solar energy, and the high vacuum they had formed can reduce the heat loss to the lowest degree, because the selective coating can transfer the perpendicular incidence radiation and diffuse radiation to the super conducting heat pipes.

The solar collector tubes take on the available absorb solar energy and heat preservation adiabatic function, even if it located in disadvantage condition, it also can arrest drain of heat. The heat pipe takes on the transfer solar energy function rapidly. These optimize combination is superior to any other ones even if it is located in the uncommon conditions.

Performance Parameter:

Degree of Vacuum ≥ 5×10ˉ3Pa

Coating: Nitrided Aluminum

Absorptivity : ≥0.93

Emissivity: ≤0.08

Startup Temperature: ≤25 °C

Highest Temp Under Sunshine: 250 °C

Freeze Resistance: -40 °C

Life ≥ 10 Years

Wind Resistance: 30m/s ( 11 Level)

Hailstone Resistance: 35mm

Material of pipe: high boron silicon glass and copper

Weight of single pipe 1.25kg 2.36kg

Size of condenser header(mm) 15 ×50

Size of single pipe¢47×1500/¢58×1800/¢70×1700





Home  |  Product Catalog  |  Split Solar Water Heating Syst  |  solar light  |  sanitary ware  |  solar intelligent controllers  |  All-glass evacuated tubes  |  Documents  |  News  |  Contact Us  |  Sitemap  |  Mobile Version

Powered by DIYTrade.com  Build your FREE website !
Find Best Price For China Products !